MEDICAL CHEMICAL CORP -- ISOPROPYL ALCOHOL, 70%, 105B AND 1051E. -- 6810-01-088-6265
===================== Product Identification =====================
Product ID:ISOPROPYL ALCOHOL, 70%, 105B AND 1051E.
MSDS Date:02/26/1991
FSC:6810
NIIN:01-088-6265
=== Responsible Party ===
Company Name:MEDICAL CHEMICAL CORP
Address:1909 CENTINELA AVE
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Info Phone Num:213-829-4304
Emergency Phone Num:800-424-9300(CHEMTREC)
Preparer's Name:P.B.
CAGE:64681
=== Contractor Identification ===
Company Name:MEDICAL CHEMICAL CORP.
Address:1909 CENTINELA AVE
Box:City:SANTA MONICA
State:CA
ZIP:90404-5057
Country:US
Phone:310-829-4304
CAGE:64681
============= Composition/Information on Ingredients =============
Ingred Name:ISOPROPYL ALCOHOL; (ISOPROPANOL) (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 70% V/V
OSHA PEL:400 PPM
ACGIH TLV:400 PPM;500 STEL
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SLIGHTLY TOXIC. INGEST OF LG QTY MAY
CAUSE DROW & LOSS OF CONSCIOUSNESS. STOM CRAMPS, PAIN, NAUS, VOMIT
& DIARR MAY ALSO OCCUR. WIDESPREAD & PRLNG EXPOS MAY RSLT IN
ABSORPTION OF HARMFUL AMTS, PARTICU LARLY IN INFANTS. INHAL OF LOW
CONCS MAY CAUSE MILD IRRIT OF NOSE & THROAT. CONCS ABOVE TLV MAY
RSLT IN(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HDCH & DROW. PRLNG SKIN CONTACT MAY
CAUSE LOCAL REDNESS, DRYNESS & CRACKING OF SKIN. SYMPTOMS OF
OVEREXPOSURE INCLUDE CNS DISTURBANCE & DIZZINESS.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN & RESPIRATORY
CONDITIONS MAY ALSO BE AGGRAVATED.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/WATER FOR AT LST 15 MINS & GET MED ATTN.
SKIN:REMOVE CONTAM CLTHG & FLUSH W/WATER. GET MED ATTN IF IRRIT
PERSISTS. INGEST:DO NOT INDUCE VOMIT IF PATIENT IS
UNCONSCIOUS/EXTREMELY DROWSY. OT HERWISE ADMIN 2 GLASSES OF WATER &
INDUCE VOMIT. GET IMMED MED ATTN EVEN IF SYMPS IMPROVE.
INHAL:REMOVE TO FRESH AIR. GIVE ARTF RESP IF NOT BRTHG. OXYGEN MAY
BE GIVEN BY QUALIFIED PERS IF (SUPP DATA)
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:71.0F,21.7C
Lower Limits:2%
Upper Limits:13%
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER IS INEFFECTIVE AGAINST ALCOHOL FIRES BUT MAY BE
USED TO COOL ADJACENT CONTAINERS.
Unusual Fire/Explosion Hazard:PYROLYSIS WILL RELEASE TOXIC GASES SUCH
AS CARBON MONOXIDE & METHANOL.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, ABSORB
W/SUITABLE ABSORBENT (SUCH AS PAPER TOWELS) & DISPOSE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . GENERALLY NOT NEEDED.
Ventilation:ORDINARY GENERAL VENTILATION IS USUALLY SUFFICIENT.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . OTHER PROT CLTHG/EQUIP USUALLY NOT REQD.
Work Hygienic Practices:WASH WELL AFTER HANDLING, ESPECIALLY BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
FIRST AID PROC:BREATHING IS DIFFICULT. GET MEDICAL ATTENTION.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:180F,82C
Vapor Pres:33 @ 20C
Vapor Density:2.1
Spec Gravity:0.876
Evaporation Rate & Reference:2.9 (N-BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS SOLUTION; CHARACTERISTIC ODOR OF
ISOPROPYL ALCOHOL.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STORE AWAY FROM OXIDIZERS.
Stability Condition to Avoid:HEAT & FLAME.
Hazardous Decomposition Products:PYROLYSIS WILL RELEASE TOXIC GASES
SUCH AS CARBON MONOXIDE & METHANOL.
==================== Disposal Considerations ====================
Waste Disposal Methods:SMALL QUANTITIES MAY USUALLY BE FLUSHED DOWN
DRAIN W/EXCESS WATER. INCINERATION IS PREFERRED METHOD OF DISPOSAL.
INSURE COMPLIANCE W/ALL FEDERAL, STATE & LOCAL GOVT REGS. AT
CONCENTRATIONS <10 PPM ISO PROPANOL IS BIODEGRADABLE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.